Description
Succeeding the channel settings of MWRI-I,
Micro-Wave Radiation Imager -Rainfall Mission (MWRI-RM) has enhanced observation abilities with
additional channels and improvements in calibration accuracy, observation sensitivity, positioning
accuracy and operational lifetime.
Satellite |
FY-3G
|
No. Channels |
13 |
Dynamic range |
3~340K |
Main-beam efficiency |
≥95% |
Channel registration |
≤2km (0.5km expected) |
Swath width |
800km |
Scan cycle |
three modes: 1.7s, 1.8s, 2.0s |
Scan error |
1ms (continuous in 30 minutes) |
Characteristics
Center frequency (GHz) |
Polarization |
Bandwidth (MHz) |
Frequency stability (MHz) |
Sensitivity (K) |
Minimum/expected accuracy (K) |
10.65 |
V,H |
180 |
10 |
0.5 |
0.8 / 0.8 |
18.7 |
V,H |
200 |
10 |
0.5 |
0.8 / 0.8 |
23.8 |
V,H |
400 |
15 |
0.5 |
0.8 / 0.8 |
36.5 |
V,H |
900 |
20 |
0.5 |
0.8 / 0.8 |
50.30 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
52.61 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
53.24 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
53.75 |
V,H |
400 |
25 |
0.5 |
0.8 / 0.8 |
89.0 |
V,H |
3000 |
25 |
0.5 |
0.9 / 0.8 |
118.7503±3.2 |
V |
2×500 |
25 |
0.8 |
1.2 / 0.8 |
118.7503±2.1 |
V |
2×400 |
25 |
0.8 |
1.2 / 0.8 |
118.7503±1.4 |
V |
2×400 |
25 |
0.8 |
1.2 / 0.8 |
118.7503±1.2 |
V |
2×400 |
25 |
0.8 |
1.2 / 0.8 |
165.5±0.75 |
V |
2×1350 |
30 |
0.8 |
1.2 / 0.8 |
183.31±2.0 |
V |
2×1500 |
30 |
0.8 |
1.2 / 0.8 |
183.31±3.4 |
V |
2×1500 |
30 |
0.8 |
1.2 / 0.8 |
183.31±7 |
V |
2×2000 |
30 |
0.8 |
1.2 / 0.8 |