Advanced Geostationary Radiation Imager (AGRI)

A multiple channel radiation imager, one of the primary instruments aboard FY-4B. Technically featured by precisely designed two-mirror structure, capable of accurate and flexible sensing in two dimensions, and minute-level fast sector scanning. Frequent earth imaging over 15 bands with off-axis three reflections of primary optic system. On-board black body available for IR calibrations at very short time intervals.

AGRI of FY-4

Primary instrument details:

FY-4B (Operational) FY-4A (R&D)
Number of bands 15 14
Spatial resolution VIS 0.5~1km 0.5~1km
near IR 2km 2km
IR 4km 4km
Temporal resolution 15min/full-disc 15min/full-disc
Sensitivity reflection bands SNR=200@ρ=100% SNR=200@ρ=100%
IR bands NEΔT=0.2K@300K NEΔT=0.2K@300K
Calibration accuracy reflection bands 3~5% 3~5%
IR bands 0.7K 1K
Demo of FY-2 VISSR scan mode. Demo of FY-4 AGRI scan mode.
Parameters of FY-4B AGRI
Band Center wave length (μm) Band width (μm) Spatial resolution(km) Sensitivity/SNR Main purpose
1 0.47 0.45~0.49 1 S/N≥90(ρ=100%) Aerosol
2 0.65 0.55~0.75 0.5 S/N≥150(ρ=100%)@0.5km S/N≥3(ρ=1%)@1km Fog, cloud
3 0.825 0.75~0.90 1 S/N≥200(ρ=100%) S/N≥3(ρ=1%) Vegetation
4 1.379 1.371~1.386 2 S/N≥120(ρ=100%) S/N≥2(ρ=1%) Cirrus
5 1.61 1.58~1.64 2 S/N≥200(ρ=100%) S/N≥3(ρ=1%) Cloud, snow
6 2.25 2.10~2.35 2 S/N≥200(ρ=100%) S/N≥2(ρ=1%) Cirrus, aerosol
7 3.75 3.50~4.00(high) 2 ≤0.7K(315K) Fire
8 3.75 3.50~4.00(low) 4 0.2K(300K) 2K(240K) Land surface
9 6.25 5.80~6.70 4 0.2K(300K) 0.9K(240K) High level water vapor
10 6.95 6.75~7.15 4 0.25K(300K) 0.9K(240K) Mid level water vapor
11 7.42 7.24~7.60 4 0.25K(300K) 0.9K(240K) Low level water vapor
12 8.55 8.3~8.8 4 0.2K(300K) 0.4K(240K) Cloud
13 10.80 10.30~11.30 4 0.2K(300K) 0.4K(240K) Surface temperature
14 12.00 11.50~12.50 4 0.2K(300K) 0.4K(240K) Surface temperature
15 13.3 13.00~13.60 4 0.5K(300K) 0.9K(240K) Cloud and water vapor